FEATURES:
MODEL IMPLICATION:
USES:
The utility model has the advantages that the utility model is provided with one normally open contact, which is suitable for charging piles, electric four wheeled vehicles, new energy vehicles, energy saving and environmental protection systems, road traffic lighting systems, programmable power supply and uninterruptible power supply equipment.
TECHNICAL PARAMETERS: (Version 1.09)
SAYOON Product Type |
SEV800AH |
Contact form | 1 NO(SPST-NO) or 1NC(SPST-NC) |
Coil Rated voltage(DC V) | DC6V,12V,24V,36V,48V,60V,72V,84V,120V,150V,DC220V,AC220V etc. |
Contact voltage(DC V) | 5-1000V |
Contact circuit rated load current (DC-1) | 800A |
Typical voltage drop across contacts per 100A | ≯80mV |
the cooling pull-in voltage at (20±5)℃ (V) | ≯70% |
the cooling drop-out voltage at (20±5)℃(V) | ≯35%,≮5% |
Working voltage range of 40 degrees celsius coil | 0.8-1.2Us |
Drop-out time(n/o contacts to open) | 80ms |
Pull-in time (n/o contacts to close) | 20ms |
connect the maximum contact bounce time | 10ms |
Disconnect the maximum contact bounce time | 7ms |
Insulation Resistance | 100MΩ |
Electric strength to resist | 50Hz/60Hz 2200VAC 1minute |
Typical fault currents which can be ruptured | 1500A/5ms at 48V DC |
Coil power (W) | H: Start 30-60,Keep 4-10 |
Temperature rise of coil (K) | ≤45 |
Temperature rise on outgoing terminal (K) | ≤65 |
Electric life | 20000 times |
Mechanical life | 300 thousand times |
Work specification | Continuous |
Contact material | Alloy |
Inrush time(Max) | 130ms |
Maximum switching current | 3000A 320VDC(More than 1 times) |
Maximum switching power | 1000kW |
Load terminal type | M10 Rose |
Coil terminal type | 0.3 square silicone wire, 390mm long |
Auxiliary contact rated load (choose) | 3A/30VDC |
Testing organization certification | CE,FCC,RoHS |
Note:As regarding to the different using environments of customers which requires different focus of the functions,and in order to improve the comprehensive properties of our products,sayoon may adjust the coil parameters,temperature rise and so on. The above parameters are for reference only, For details, please refer to the guidelines for selection and use of the SAYOON DC contactor.
LOAD CHARACTERISTIC CURVE:
INSTALLATION DIAGRAM:
WIRING DIAGRAM:
COIL TEMPERATURE CURVE:
MECHANICAL ABILITY and USE of the ENVIRONMENT:
Contact lead M10 tightening torque(N.m) | ≯20.5 appropriate |
Coil lead mode | Wire dipping tin (Red positive and black negative) |
Ambient temperature | -40~+85℃ |
Relative humidity | +20℃ 98% |
Vibration freq. atthe fixed position | 3G, 1~50Hz amplitude 0.5mm |
concussion | (60~100) time/minute、Acceleration≤4g |
Altitude | 2000米 |
Installation direction | Random |
International Protection | IP68 |